Default values of decoding parameters – Adesso NuScan 2100 Series User Manual
Page 6

DEFAULT VALUES OF DECODING PARAMETERS
Function
Code
Default
Value
Code 39
Enable
ITF 2 of 5
Enable
Chinese Post Code
Disable
UPC/EAN/JAN
Enable
Coda bar
Enable
Reading codes
MSI
Disable
Selection Code
128
Enable
Code 93
Enable
ITAT
Disable
EAN-128
Disable
MATRIX 25
Disable
Italian Pharmacy
Disable
ISSN/ ISBN
Disable
Codes
Standard
Code 39
Start/stop characters Not transmitting
Check digit
Disabled
Concatenation
Off
Interleaved
Length
6-32
digits
2 of 5
Check digit
Disable
Chinese Post
Length
10~16 digits
Code
Check
digit
Transmit
Format
All
Addendum
Disable
UPC-E=UPC-A
Disabled
UPC/EAN/JAN
UPC-A leading digit
Transmit
UPC-A check digit
Transmit
UPC-E leading digit
Transmit
UPC-E check digit
Transmit
Type Standard
Coda bar
Start/stop characters
A, B, C, D
Length 6~32
digits
Code 128
FNC 2 append
Disable
Check digit
Disable
MSI
Length
Variable
Check digit
Transmit
Italian Pharmacy
Transmit "A"
Character
Not transmitting
MATRIX 25
Length
Fix 10 digits
Check digit
Disable
Note: The configuration of the items with asterisk
(
) is effective when being appointed in advance.
4
4. PROGRAM PROCEDURE USING BARCODE
MENUS
NO
NO
YES
YES
5