Balboa Water Group Quiet-Flo Air Switch PushButton Blower Control User Manual

Quiet-flo, Heated blower with on/off air button, Timers

Advertising
background image

Quiet-Flo

TM

Heated Blower with On/Off Air Button

Timers

When the system motor is activated, a 30 minute timer is

automatically started. Once the 30 minutes run-time has expired,

any equipment automatically turns off.
When the blower is turned off, it waits for 15 minutes and then

runs a two-minute purge cycle. A purge cycle is designed to

remove standing water from the air system, which helps maintain

a sanitary bath system.

Blower Operation

Air switch operation:

1st Press: High speed.

•

2nd Press: Med. speed.

•

3rd Press: Low speed.

•

4th Press: Wave Mode.

•

5th Press: Off.

•

In Wave Mode, the blower starts at high speed,

•

reduces to low speed, then rises to high speed.

Then the cycle resumes.

Optional Heated Quite-Flo Blower

Any time the blower turns on, the heater turns on with it.

•

Line Voltage

Air Button with Quiet-Flo Blower

Wiring Diagram

Air Switch Button

(13070-XX - basic style*)

8’ Water

Detect Cable

(99742)

(Optional)

Air Switch Quiet-Flo Blower

with 600W Heater

(8141-6220)

Specifications / Overview

120 VAC 60 Hz.

•

30 minute timer.

•

Purge cycle.

•

4 Modes of operation:

•

Speed 3: High speed.

Speed 2: Med. speed.

Speed 1: Low speed.

Wave Mode: Speed diminishes to low, then returns to

high (within 12 seconds).

Control board mounted in blower housing.

•

If the main power is interrupted while the timer is

•

running, the system will return to standby mode when

power is restored.