Wiring diagrams, Wheel rotation, Single speed, single phase motor – COOK CFS User Manual

Page 3: Typical damper motor schematic

Advertising
background image

3

Motor

1
2

3

4

5

6

Together

High Speed

Line

L1

L2
L3

1
2

3

4

5

6

Open

Low Speed

Line

L1

L2
L3

Motor

Wiring Diagrams

Fan

Motor

Damper

Motor*

Second

Damper

Motor

Transformer**

Transformer**

L3
L2
L1

Lock off all power sources before unit is wired to
power source.

Leave enough slack in the wiring to allow for motor

movement when adjusting belt tension. Some frac-
tional motors have to be removed in order to make
the connection with the terminal box at the end of the
motor. To remove motor, remove bolts securing
motor base to power assembly. Do not remove motor
mounting bolts.

Follow the wiring diagram in the discon-
nect switch and the wiring diagram pro-
vided with the motor. Correctly label the
circuit on the main power box and always
identify a closed switch to promote safety
(i.e., red tape over a closed switch).

Wheel Rotation

Test the fan to ensure the rotation of the wheel is the

same as indicated by the arrow marked Rotation.

Wiring Diagrams

When ground is required, attach to ground A or B with no. 6 thread forming
screw. To reverse, interchange T-1 and T-4.

Single Speed, Single Phase Motor

To reverse, interchange any 2 line leads.

When ground required, attach to ground A or B with No. 6 thread forming
screw. To reverse, interchange T-1 and T-4 leads.

2 Speed, 2 Winding, Single Phase Motor

2 Speed, 1 Winding, 3 Phase Motor

To reverse, interchange any 2 line leads. Motors require magnetic control.

Single Speed, Single Phase, Dual Voltage

2 Speed, 2 Winding, 3 Phase

When ground required, attach to ground A or B with No. 6 thread forming
screw. To reverse, interchange T-5 and J-10 leads.

To reverse: High Speed-interchange leads T

11

and T

12

.

Low Speed-interchange leads T

1

and T

2

. Both Speeds-interchange any 2

Typical Damper Motor Schematic

For 3 phase, damper motor voltage should be the same between L

1

and L

2

. For

single phase application, disregard L

3

. * Damper motors may be available in 115,

230 or 460 volt models. The damper motor nameplate voltage should be verified
prior to connection. ** A transformer may be provided in some installations to cor-
rect the damper motor voltage to the specified voltage.

T-1

T-4

Ground B

L2

L1

Ground A

Line

Ground A

Ground B

T-1

T-4

Low Speed

High Speed

L 1

L 2

Line

Ground B

J-10

T-5

Ground A

Link A

Link B

Low Voltage

Line

L 2

L 1

Ground A

Link A & B

L1

L 2

Line

Ground B

T-5

J-10

4 5 6

1

7

2
8

3
9

L1 L2 L3

4 5 6

7 8 9

1 2

3

L1 L2 L3

Low Voltage

208/230 Volts

High Voltage

460 Volts

3 Phase, 9 Lead Motor
Y-Connection

7

1

6

7 8 9

4 5 6

1 2

3

Low Voltage

208/230 Volts

High Voltage

460 Volts

8

2

4

9

3

5

L1

L3

L2

L1

L3

L2

3 Phase, 9 Lead Motor
Delta-Connection

Airfoil

Proper Wheel Rotation

Advertising