8.0 ADJUSTMENTS

8.1 VENTURI

ADJUSTMENT

This model has an air shutter that has been factory set open according to the chart below:

Closing the air shutter will cause a more yellow fl ame, but can lead to carboning.
Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting
from the burner ports. The fl ame may not appear yellow immediately; allow 15
to 30 minutes for the fi nal fl ame color to be established.

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!

NOTE: It is important that the venturi sits down tight on the orifi ce.

49.3

VENTURI

BURNER

AIR

SHUTTER

OPENING

AIR SHUTTER OPENINGS

LP

3/16” DIA

NG

1/16” DIA

8.2 FLAME

CHARACTERISTICS