TROUBLESHOOTING (continued)

Problem

Possible Cause

Corrective Action

Excessive

Condensation in

Food Compartment.

Water pressure is too high (DFW/

DFWT/DFWF-200/250).

Verify that the Water Pressure Regulator is set to 20

- 25 PSI. Adjust accordingly.

Programming and or

SHO and H2O

values were adjusted improperly

(

Timer Models only).

Reprogram the SHO and H2O values as described

in the Programming section of this manual.

Excessive Steam

escapes from front

or sides of Steamer.

Worn or damaged Top Cover Gasket. Replace Top Cover Gasket.
Top Cover out of adjustment.

Adjust Top Cover according to the Maintenance sec-

tion of this manual.

Steam Generator’s

surface becomes

flooded (fills with

excess water).

Insufficient pre-heat time.

Remove excess water from the Generator surface

and allow the unit 30 minutes of pre-heat time.

The Green Momementary Switch is

pressed for longer than 1 second.

Follow the “one in twenty” rule. Refer to the

Operation section of this manual.

Water Pressure Regulator is not

installed (DFW/DFWT/DFWF-200/

250).

Verify that a Water Pressure Regulator is installed

and set to 20 - 25 PSI. Adjust accordingly.

Water pressure is too high (DFW/

DFWT/DFWF-200/250).

Verify that a Water Pressure Regulator is installed

and set to 20 - 25 PSI. Adjust accordingly.

Programming and/or

SHO and H2O

values were adjusted or changed

improperly (

Timer Models only).

Reprogram the Control Board to the recommended

settings. Refer to the Programing section of this

manual.

Solenoid Valve is leaking due to

debris trapped inside the plunger

(DFW/DFWT/DFWF-200/250).

Attempt to flush the debris out of the valve by rap-

idly operating the unit on a number of “single shot”

cycles and then letting it rest. If the unit still leaks,

disassemble the Solenoid Valve and clean out the

plunger. Reassemble the unit and test again. If

a leak is still present, replace the Solenoid Valve.

Contact your maintenance person or Authorized

Service Agency.

The Water Pump and/or its Check

Valves are clogged or damaged.

Verify that the filter is present in the water tank.

Disassemble and clean pump. Replace Check

valves if damaged.

Improper Daily/Monthly cleaning.

Follow the Daily/Monthly cleaning procedures care-

fully.

The Generator surface temperature

is too low.

Verify that the Generator surface temperature is

between 380° - 420° F (193 - 215° C).

Insufficient or excessive calcium/

mineral deposits on the Generator

surface.

Verify that a thin layer of calcium/mineral deposits

is present on the Generator surface. Refer to the

Maintenance section of this manual.

There is no pre-strainer or filter on

the water line (DFW/DFWT/DFWF-

200/250).

The unit was supplied with a strainer. If missing,

install strainer.

Solenoid Valve is installed incorrectly

(DFW/DFWT/DFWF-200/250).

If the Solenoid Valve was replaced, verify that the :

”IN” and “OUT” labels on the valve correspond to

the water flow.