Nor-Lake NOVA Refrigerators and Freezers User Manual
Page 8

Model
BTU @ 100°F Solid Dr
& 86°F Glass Dr
Refrig't
Voltage
Amps
Exp valve
ELEC
VAPORIZER
NR241SSS/0R
850 @ +28°F EVAP
R134a
115/60/1
0.53
YES
NO
NR241SSG/0R
1260 @ +28°F EVAP
R134a
115/60/1
0.53
YES
NO
NR242SSS/0R
850 @ +28°F EVAP
R134a
115/60/1
0.53
YES
NO
NR242SSG/0R
1260 @ +28°F EVAP
R134a
115/60/1
0.53
YES
NO
NR522SSS/0R
1580 @ +28°F EVAP
R134a
115/60/1
0.9
YES
NO
NR522SSG/0R
2450 @ +28°F EVAP
R134a
115/60/1
0.9
YES
NO
NR524SSS/0R
1580 @ +28°F EVAP
R134a
115/60/1
0.9
YES
NO
NR524SSG/0R
2450 @ +28°F EVAP
R134a
115/60/1
0.9
YES
NO
NR803SSS/0R
2250 @ +28°F EVAP
R134a
115/60/1
1.1
YES
NO
NR803SSG/0R
3580 @ +28°F EVAP
R134a
115/60/1
1.1
YES
NO
NR806SSS/0R
2255 @ +28°F EVAP
R134a
115/60/1
1.1
YES
NO
NR806SSG/0R
3580 @ +28°F EVAP
R134a
115/60/1
1.1
YES
NO
PR242SSS/0R
925 @ +28°F EVAP
R134a
115/60/1
0.53
YES
NO
PR242SSG/0R
1860 @ +28°F EVAP
R134a
115/60/1
0.53
YES
NO
PR524SSS/0R
1715 @ +28°F EVAP
R134a
115/60/1
0.9
YES
NO
PR524SSG/0R
3655 @ +28°F EVAP
R134a
115/60/1
0.9
YES
NO
PR806SSS/0R
2170 @ +28°F EVAP
R134a
115/60/1
1.1
YES
NO
PR806SSG/0R
5110 @ +28°F EVAP
R134a
115/60/1
1.1
YES
NO
WR331SSS/0R
1370@ +28°F EVAP
R134a
115/60/1
0.76
YES
NO
WR722SSS/0R
2635@ +28°F EVAP
R134a
115/60/1
1.36
YES
NO
PWR332SSS/0R
1500@ +28°F EVAP
R134a
115/60/1
1.0
YES
NO
PWR724SSS/0R
2875@ +28°F EVAP
R134a
208-230/60/1
1.82
YES
NO
NF241SSS/0R
1820 @ -10°F EVAP
R404a
115/60/1
4.7
YES
NO
NF242SSS/0R
1820 @ -10°F EVAP
R404a
115/60/1
4.7
YES
NO
NF522SSS/0R
2855 @ -10°F EVAP
R404a
115/60/1
6.9
YES
NO
NF524SSS/0R
2855 @ -10°F EVAP
R404a
115/60/1
6.9
YES
NO
NF803SSS/0R
3505 @ -10°F EVAP
R404a
115/60/1
7.4
YES
NO
NF806SSS/0R
3505 @ -10°F EVAP
R404a
115/60/1
7.4
YES
NO
NX211SSS/0R
3015@ -35°F EVAP
R404a
115/60/1
7.2
YES
YES
NX211SSG/0R
4140 @ -35°F EVAP
R404a
115/60/1
7.2
YES
YES
NX482SSS/0R
3520 @ -35°F EVAP
R404a
115/60/1
11.6
YES
YES
NX482SSG/0R
5835 @ -35°F EVAP
R404a
115/60/1
11.6
YES
YES
NOTES:
1) Cord and plug are not supplied with these units
2) Compressor size to be determined by a qualified refrigeration technician based on the delivered BTU rating
at the unit and actual jobsite requirements.
3) BTU rating shown is the required BTU's at the evap coil.
4) Standard five year compressor warranty does not apply to these units.
5) Condensate removal is the responsibility of the customer. A short drain line exiting the unit cooler section on
the top of the cabinet is provided for the purpose of extending.
6) Legs are standard on remote systems as they are generally hard piped to the condensing unit.
7) The solenoid valve mounted on the cabinet is factory wired to the control. No connections are required between
the cabinet and the remote compressor.
REMOTE REFRIGERATION DATA
8
06/11 Rev. B 127717