Inputs/outputs, Printer installation – Nor-Lake Blast Chillers & Blast Chillers-Freezers User Manual

Page 37

Advertising
background image

--

IIN

NS

ST

TA

AL

LL

LA

AT

TIIO

ON

N M

MA

AN

NU

UA

AL

L --

09/12 Rev. B 143573

37

C

Compressor

R

Door resistance

D

Defrost

A

Alarm

FE

Evaporator fan

DI1

Inputs state micro

FC

Condenser fan

DI2

Inputs state thermostat

L

Sterilization

FAN

Evaporator fan speed

INPUTS/OUTPUTS

Press menu/esc to select the desired menu

Inputs/Outputs

Use the keys up and down to display

Esc

Press enter to gain access to the mode for displaying inputs and outputs

The display shows

Room 21°F

Probe 59°F








Use the keys up and down to scroll the data to display

Room 21°F

Room: Room air temperature

Probe 59°F

Probe: Core temperature – see core probe section

Food 93°F

Food: under surface probe – see core probe section

External 90°F

External: over surface probe – see core probe section

Evap. 14°F

Evaporator and Condenser temperature values

Cond. 70°F

Outputs state

C D FE FC L R A

1 = relay activated

1 0 0 1 1 0 0

0 = relay de-activated

DI1 DI2 FAN

Digital inputs state and evaporator

0 1 80

fan speed



Press menu/esc to exit


PRINTER INSTALLATION

The printer is not supplied as standard equipment .

Should you purchase the printer, please follow the installation instructions to install.

Advertising