Electrical connections, Checking the motor rotation (“jog” feature), Shelving – Power Soak 29222 INSTRUCTIONS INSTALLATION PS-200 User Manual

Page 24

Advertising
background image

20

Electrical Connections

The final electrical connections between the Power Soak and the electrical
supply must be made by a licensed electrician. The Power Soak has
several options for motors and heater. Review the information tag for
determining the specific requirements of the machine being installed (see
Verify the Electric Requirements section of this instruction booklet).

Checking the Motor Rotation (“JOG” Feature)

The motor must rotate in the correct direction in order for the Power Soak
to function properly. An arrow indicating the direction of rotation is located
on the pump housing. The control unit has a feature that allows the motor
to be “jogged” for checking the rotation even if the wash tank is empty.
Press and hold the green START button for 5 to 10 seconds and watch the
fan blades inside the motor fan cover. After holding the start button for the
5 to 10 second delay, the motor will start for a few rotations and
automatically stop if the wash tank is empty. If the wash tank is full of
water the motor will continue to run even if the direction of rotation is not
correct. When the wash tank is full, the red STOP button must be pressed
to stop the motor. Running the motor in the wrong direction does not
damage the motor or pump, but the pump will not circulate water in the
wash tank correctly.


Shelving

Reinstall any shelving that was removed for convenience of installation. If
the shelving is damaged or corroded, it is recommended that the shelving
be replaced.

THE MOTOR MUST ROTATE IN THE CORRECT DIRECTION FOR THE

MACHINE TO OPERATE PROPERLY. USE THE “JOG” FEATURE TO

CHECK THE MOTOR ROTATION

IMPORTANT

Arrow indicating the
direction of rotation is
located on the pump
housing

Advertising