Vaddio AutoVIEW IR Sensor Kit User Manual

Page 6

Advertising
background image

AutoVIEW IR Sensor Kit

AutoVIEW IR Sensor Kit Manual 341-233-1 Rev. C

Page 6 of 8

Basic Installation
The AutoVIEW IR Sensor is a modified Optex Sensor usually used in automatic door systems.

1) Affix the mounting template to the sensor mounting position
2) Drill or cut a 5-1/8” (130mm) round mounting hole for the sensor

Recommended distance to the nearest wall is 12” (304.8mm)












3) Hold the sensor, keeping the door markers pointed toward the nearest wall
4) Connect the Cat-5e cable
5) Press the spring steel mounting clips against the side of the sensor and place sensor in the mounting

hole. The spring steel clips will provide a tension fit. Not tile race is needed

6) Adjust the sensor according to the Otpex manual and click on the front acryilic lens cover.
7)




















8) Connect the Cat-5e cable from the AutoVIEW IR Sensor to the end of the AutoVIEW IR Control Interface

clearly marked IR Sensor.

9) Connect to the 2-wire trigger OUT on the AutoVIEW IR Control Interface to the trigger IN that is to be

controlled.

10) Test and adjust to requirements.






Drill a 5-1/8”
hole for the
sensor

Side view of
sensor

Spring Steel
mounting
clips

WALL

Set the door markers on the sensor
toward the nearest wall

Advertising