3.) The MicVIEW units can be linked together by standard Straight-through 6-Pin
RJ-11 cables. The Link light will illuminate when the link is correctly established.

MicVIEW
Back Panel

(1) PWR – Power Connector.
(2) MICROPHONE LOGIC OUTPUT +5V – status line outputs for indicating which microphone is active.
(3) CONTROL – RS-232 Port for external control of the MicVIEW functions.
(4) LINK IN/OUT – Link Port for connecting multiple MicVIEW units for expanded functionality.
(5) AUDIO LINE OUTPUT – Analog line level output for connection to amplifier or codec for broadcast or
transmission of audio.
(6) MICROPHONES – Twelve 3-Pin connectors for connecting external microphones with 24V phantom
power.
(7) MUTE – Connecting these pins mutes microphones 2-12 and any linked MicVIEW systems.

1

2

3

4

5

6

7

MICROPHONE CONNECTORS

Audio Power By
SOUND CONTROL TECHNOLOGIES

4 3 2 1

+ - 5

+ - 5

+ - 5

+ - 5

4 3 2 1

+ - 5

+ - 5

+ - 5

+ - 5

4 3 2 1

+ - 5

+ - 5

+ - 5

+ - 5

1 2 3 4 5 6 7 8 9 10 11 12

+ - 5

LINE

OUTPUT

IN OUT

LINK

MICROPHONE LOGIC OUTPUT

MUTE

CONTROL

C

12 VDC

1.5A

continued on next page.

1.) Connect the (+), (-), and (S)hield pins on microphone Inputs 1-12 to the respec-
tive microphones.
• Microphones 1 and 2 cam be switched to line-level or mic-level with or without
phantom power. Press the Input x Mic button on the front to toggle between mic-
level and line-level, and press Input x Phantom Power to toggle phantom power
ON/OFF.

2.) Connect the (+), (-), and (S)heild pins on the Line Output to the line-level on a

Setting Up the
MicVIEW

codec or amplifier.
• To connect the line output to a phono
cable, connect (+) to the center pin on the
phone cable and the (S) on the MicVIEW
to the negative wire on the phone cable.

2

• If two MicVIEW units are to be used to-
gether, connect the Link OUT of the Mas-
ter system to the Link IN of the slave uni
(see figure at right). Continue by connect-
ing the Link OUT of the slave unit to the
Link IN of the Master system.
• If multiple MicVIEW units are to be used
together, (up to eight units) connect the
Link OUT of the Master system to the Link
IN of the slave unit (see figure at right).
Continue by connecting the Link OUT of
the slave unit to the LINK IN of the sec-
ond slave unit. Connect the Link OUT of
the last slave to the LINK IN of the Master
system.

WARNING

DO NOT connect (-) and (S) together as they may
damage the MicVIEW.

To Configure as a Slave Unit – Discon-
nect the power. Press and hold Input 2
Mic/Line and Instructor priority while
reconnecting power.
To Configure as a Master – Disconnect
the power. Press and hold Input 2
Phantom Power and Push-To-Talk while
reconnecting power.

NOTE: In multiple unit setup only one unit can be
configured as the Master.

NOTE: Only the Master unit will provide Audio
Output

MASTER

SLAVE

LINK

IN

LINK

OUT

LINK

IN

LINK

OUT

MASTER

SLAVE

SLAVE

LINK

IN

LINK

OUT

LINK

IN

LINK

OUT

LINK

IN

LINK

OUT