Vaddio PresenterPOD System User Manual

Page 5

Advertising
background image

PresenterPOD System

PresenterPOD System

Document Number 342-0212 Rev. B

Page 5 of 12

The PresenterPOD Interface -

Single PresenterPOD System (no scale)


























1) Power LED: Blue LED power indicator light
2) Power Jack: 5.5mm OD x 2.5mm ID, Positive Center
3) Recessed Button (for future use - not currently used)
4) POD 1 RJ-45 Jack: Supplies power to the PresenterPOD and exchanges data between POD and Interface.

The Interface can support two PresenterPODs with Cat-5e cables at a distance of up to 100’ (30.48m) each.

5) POD 1 Trigger Outs (short to ground): The icons for triggers are arranged in the same shape as the

buttons on the PresenterPOD.
a. 5a is the large round button on the left side of the PresenterPOD
b. 5b is the center, small and square button which can be used as a PIP on/off for AutoPresenter or as an

ordinary trigger. Default for this button is momentary for PIP on/off, but can be changed to latching.

c. 5c is the large round button on the right side of the PresenterPOD
d. 5d is a dual purpose button. It serves as a Logo button, is back-lit blue while the power is on and it can

be used as a trigger that turns red when triggered.

e. Two ground pins on the Interface (for ease of wiring)

6) POD 2 RJ-45 Jack: Supplies power to the PresenterPOD and exchanges data between POD and Interface

at a distance of up to 100’ (30.48m) each.

7) POD 2 Trigger Outs (short to ground): Same controls, button pushes and icons as POD 1
8) Trigger Settings: The trigger outs can be assigned as latching or momentary triggers (see table below).
Note:

Dip switch 9 combines the PODs logic together and supply up to 8 triggers out (one at a time) using two

pods. With dip switch 9 up, the PODs act independently allowing two triggers at a time to separate input devices.

Dip Switch

DOWN Function

UP Function

SW1

POD 1 - SW1 Latching Trigger (default)

POD 1 - SW1 Momentary Trigger

SW2

POD 1 - SW2 Latching Trigger

POD 1 - SW2 Momentary Trigger (default)

SW3

POD 1 - SW3 Latching Trigger (default)

POD 1 - SW3 Momentary Trigger

SW4

POD 1 - SW4 Latching Trigger (default)

POD 1 - SW4 Momentary Trigger

SW5

POD 2 - SW1 Latching Trigger (default)

POD 2 - SW1 Momentary Trigger

SW6

POD 2 - SW2 Latching Trigger

POD 2 - SW2 Momentary Trigger (default)

SW7

POD 2 - SW3 Latching Trigger (default)

POD 2 - SW3 Momentary Trigger

SW8

POD 2 - SW4 Latching Trigger (default)

POD 2 - SW4 Momentary Trigger

SW9

Logic Combined - 8 Triggers on 2 PODs (default)

Logic - PODS behave independently

SW10

N/A - Future Functionality (default)

N/A - Future Functionality

5a

5b

5c

5d

5e

5b

5a

5c

5d

Cat-5e Cable

PresenterPOD 1

(no scale): Buttons

marked to correspond to the icons on
the Trigger Outs of PresenterPOD 1.
The PresenterPOD is connected to the
POD 1 Interface with a Cat-5e cable
(up to 100’ /30.48m).

Advertising