VISCA Device Setting Command

Before starting control of the BRC-Z700, be sure to send
the Address command and the IF_Clear command using
the broadcast function.

For VISCA network administration

Address
Sets an address of a peripheral device. Use when
initializing the network, and receiving the following
network change message.

Network Change
Sent from the peripheral device to the controller when
a device is removed from or added to the network. The
address must be re-set when this message is received.

Packet Note

Address

88 30 01 FF

Always broadcasted.

Network Change

X0 38 FF

X = 9 to F: BRC-Z700 address + 8

VISCA interface command

IF_Clear
Clears the command buffers in the BRC-Z700.
When cleared, the operation currently being executed
is not guaranteed.

Command Packet

Reply Packet

Note

IF_Clear

8X 01 00 01 FF

X0 50 FF

IF_Clear (broadcast)

88 01 00 01 FF

88 01 00 01 FF

X = 1 to 7: BRC-Z700 address (For inquiry packet)
X = 9 to F: BRC-Z700 address +8 (For reply packet)

VISCA interface and inquiry

CAM_VersionInq
Returns information on the VISCA interface.

Inquiry

Inquiry Packet Reply Packet

Description

CAM_VersionInq 8X 09 00 02 FF Y0 50 GG GG HH HH JJ JJ KK FF GGGG = Vender ID

(0001: Sony)
HHHH = Model ID
0501: BRC-H700
0502: BRU-H700
0505: BRC-Z700
JJJJ = ROM revision
KK = Maximum socket # (02)

X = 1 to 7: BRC-Z700 address (For inquiry packet)
X = 9 to F: BRC-Z700 address +8 (For reply packet)