Communication Specification

Communication Speed: 9600 bps (default)

Start bit: 1

Stop bit: 1

Data bits: 8

Parity: None

No Flow control


NOTE:

The Vaddio ClearVIEW HD-20 Control Protocol is similar, but not identical to the Sony® VISCA™

command set in order to be compatible with several popular control devices. Not all VISCA commands are

supported and there are many HD-20 specific commands in the following Command and Inquiry Lists.

HD-20 Command List (1/2)

Command Set

V

Command

Command Packet

Comments

AddressSet

Y

Broadcast

88 30 01 FF

Address Set

IF_Clear

Y

Broadcast

88 01 00 01 FF

I/F Clear

CommandCancel

Y

81 2p FF

p: Socket No(=1 to2)

CAM_Power

Y

Y

On

Off

81 01 04 00 02 FF

81 01 04 00 03 FF

Power On/Off

CAM_Zoom

Y

Y

Y

Y

Y

Y

Y

Stop

Tele(Standard)

Wide(Standard)

Tele(Variable)

Wide(Variable)

Direct

Direct(Variable)

81 01 04 07 00 FF

81 01 04 07 02 FF

81 01 04 07 03 FF

81 01 04 07 2p FF

81 01 04 07 3p FF

81 01 04 47 0p 0q 0r 0s FF

81 01 7E 01 4A 0V 0p 0q 0r 0s FF

p:0(Slow) to 7(Fast)

p:0(Slow) to 7(Fast)

pqrs:Zoom Pos 0x000-0x6400

*

V:(Speed) 0-7

CAM_Focus

Y

Y

Y

Y

Y

Y

Y

Y

Y

Stop

Far(Standard)

Near(Standard)

Far(Variable)

Near(Variable)

AutoFocus

ManualFocus

Auto/Manual

Direct

81 01 04 08 00 FF

81 01 04 08 02 FF

81 01 04 08 03 FF

81 01 04 08 2p FF

81 01 04 08 3p FF

81 01 04 38 02 FF

81 01 04 38 03 FF

81 01 04 38 10 FF

81 01 04 48 0p 0q 0r 0sFF

Supported as ‘Standard

Supported as ‘Standard

pqrs:0x000-0xC00

*

CAM_WB

Y

Y

Auto

Manual

81 01 04 35 00 FF

81 01 04 35 05 FF

CAM_RGain

Y

Y

Y

Y

Reset

Up

Down

Direct

81 01 04 03 00 FF

81 01 04 03 02 FF

81 01 04 03 03 FF

81 01 04 43 00 0p 0q 0rFF

prq:000-0x27f

CAM_BGain

Y

Y

Y

Y

Reset

Up

Down

Direct

8x 01 04 04 00 FF

8x 01 04 04 02 FF

81 01 04 04 03 FF

81 01 04 44 00 0p 0q 0rFF

prq:000-0x27f

CAM_AE

Y

Y
Y
Y

Full Auto

Manual

Shutter Priority

Iris Priority

81 01 04 39 00 FF

81 01 04 39 03 FF

81 01 04 39 0A FF

81 01 04 39 0B FF

Auto Exposure Mode

Manual Control Mode

Shutter Priority Mode

Exposure Priority Mode (default)

CAM_Iris

Y

Y

Y

Y

Reset

Up

Down

Direct

81 01 04 0B 00 FF

81 01 04 0B 02 FF

81 01 04 0B 03 FF

81 01 04 4B 00 00 0p 0q FF

pq:0x0-0x0B

CAM_Gain

Y

Y

Y

Y

Reset

Up

Down

Direct

81 01 04 0C 00 FF

81 01 04 0C 02 FF

81 01 04 0C 03 FF

81 01 04 4C 00 00 0p 0q FF

pq:0x0-0x24

*

Zoom and Focus Data:

CAM_Zoom: Range(0x000–0x6400)

CAM_Focus: Range (0x000-0xC000) dependent on Zoom Position


Pin #

RJ-45 RS-232 and IR Out Pins

1)

Unused

2)

Unused

3)

Unused

4)

IR Output (Diff Signal to Quick-Connect)

5)

IR Ground (Diff Signal to Quick-Connect)

6)

GND (GND of IR Short Range - Pin 3)

7)

RXD (from TXD of control source)

8)

TXD (to RXD of control source)

12345678

Advertising