B
5 WATT
FUSE F1
XFRM
insert #5858
pic here
SEE LAYOUT DIAGRAM
REPLACEMENT TABLE
LEAD LOOP MUST NOT BE ABOVE TOP OF RESISTOR
WITHOUT CROWBAR WITH CROWBAR
N.A. CE N.A. CE
1. ADD AMPLE RTV UNDER ENTIRE BASE OF OUTPUT COIL L1
6. FIT #8921 FLAT WASHER BETWEEN #3501 BELL WASHER AND
#8667 SHOULDER WASHER FOR Q2, Q10 U30 AND U31.
*NOTE: IF THE NX520P MODEL IS BEING USED AS A
REFERENCE, NOTE THAT THE HORN OF THE EF500P
IS WIRED OPPOSITE TO THAT OF THE NX520P.
3. #5858 APPLY A RING OF RTV
ON CAPS SLEEVE AS SHOWN.
CH1255 CH1255E CH1255 CH1255E
#2415 #2482 #2465 #2479
F 5A F3.15A F 7A F 5A
8. M1159, PARTS REFERENCE TABLE
**************IMPORTANT******************
2. LEADS FOR 5 WATT RESISTORS MUST BE BENT ON THE MACHINE
7. PC7398, ADD CROWBAR CIRCUIT AND CHANGE
THE FUSE VALUE AT THE SAME TIME.
5. Q11 ONLY: MOUNT #8871 4-40 SCREW WITH HEAD ON BOTTOM.
#8793 NUT AND 3501 WASHER ON TOP.
M1159 PRODUCTION NOTES