Stair Code Compliance

In order to meet the AC174 Requirement for stair loading, follow one of the methods below:

3

2

1

AZEK 1x6 Decking
attached to
Stringers using (2)
#7 x 2 1/4” Screws

Attach 2 x 4 treated pine
centered under treads using
pneumatic framing nailer.
Nail positions as shown.

3 1/4” x .0131
roundrive framing
nail in locations
shown using
pneumatic nailer.

AZEK Deck Board
attached to Stringers
using 2 Screws/
Stringers.

Angle
Brackets

AZEK Deck Board
(Typical)

AZEK
Deck
Tread

Treated Pine

Stair Stringer

9.00”

Maximum

26.00” Minimum

7.50”

4.25”

1.875”

49.5”

36”

24.0”

17.25”

Installing Stairs

• Stairs should be constructed per local code requirements.

• Use XLM Riser Board or a AZEK ripped Rim Joist Covers for riser installation.