2 serial mode dip switch settings, 3 monitor address dip switch settings, 4 example – Beijer Electronics RBC EN User Manual
Page 9: Serial mode dip switch settings, Monitor address dip switch settings, Example
Advertising

Hardware
4. Make the desired DIP switch settings.
5. Replace the back cover.
1.2.2
Serial Mode DIP Switch Settings
DIP switch 5 is used to set COM A and COM B in RS232 or RS485 mode.
Mode
DIP switch 5
RS485
ON
RS232 (default)
OFF
1.2.3
Monitor Address DIP Switch Settings
DIP switches 1–4 are used to set the monitor addresses.
Address
DIP switch 1
DIP switch 2
DIP switch 3
DIP switch 4
0
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
ON
9
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
1.2.4
Example
1
2
3
4
5
This example sets the address to 5 and the mode to RS232.
Beijer Electronics, MAEN986C
9
Advertising