Low battery / no battery – Beijer Electronics iX Panel K70 EN User Manual
Page 40

Fault Tracing
The iX Panel K70 is working, but one or more keys are
not working
1. Check that the flex cables are correctly fitted.
2. Replace the front according to the
section.
Lines in display has wrong color or the display picture
is shifted
1. Check if the display has a wide vertical or horizontal area across the
display. It should be at least 2-3 cm wide with a grey or black color. See
Replacing the Display/Display Cable
for instructions on how to correct this.
2. Make sure the display cable is correctly fitted.
3. Make sure the display cable is not folded or damaged in any way. Replace the
display cable according to the
Replacing the Display/Display Cable
section.
Low battery / No battery
1. Connect iX Panel K70 to an external power source to automatically charge
the battery.
Beijer Electronics, MAEN002