2 / INSTALLING YOUR APPLIANCE

EN

• ENVIRONMENTAL PROTECTION

— The cooker hood should be placed at a
distance of 65-75cm (26-30inch) from the
cooking surface for the best effect.
See Pic 1.

— Install the hook on a suitable place once
the installation height is fi xed, and keep it in
line. See Pic 2.

— Install the extension tube and chimney
on the cooker hood. See Pic 3.

— Put the cooker hood on the hook. After
adjusting the position, fi x the body with
safty screw. See Pic 4.

Pic 1

Pic 2

Pic 3

Pic 4

Pic 5

Note

The two safty vents are positioned on
the back casing, with diameter of 6mm

Note

—

Any installation work must be ca-

rried out by a qualifi ed electrician or com-
petent person.

—

Do not connect the ducting system of

the hood to any existing ventilation system
which is being used for any other applian-
ce, such as warmer tube, gas tube, hot
wind tube.

—

The angle of the bend of the ventilation

pipe should not be less than 120º; you must
direct the pipe horizontally, or, alternatively,
the pipe should go up from the initial point
and should be led to an outer wall.

—

After the installation, make sure that the

cooker hood is level to avoid greasecollec-
tion at on end. See Pic. 5

Right

Wrong