6. Locate cables and connectors so as to avoid coupling from high frequency circuits.

7. If a mulilayer board design is used, make no cuts in the ground or power planes

and be sure the ground plane covers all traces.


8. Minimize the number of through-hole connections on traces carrying high

frequency signals.


9. Avoid right angle turns on high frequency traces. Forty-five degree corners are

good, however, radius turns are better

5.1.1 Grounding

Pins 26 and 41 are for grounding. Connect all of them to the same ground-layer or a
big ground-area on your board. The ground-area should completely cover the area
below and around the module and the regulator. Make the connections as wide as
possible. For better RF-perfomance, connect the metal-housing to ground, very near
the ground-pins of the module.


5.1.2 Power Supply 5V (5V Models)

A power supply with 5.0V DC +/- 5% (5V models) and a minimum power of 1.5A is
strictly required to supply this module. The supply-regulator should be placed as close
to the module as possible (about 5cm or nearer). The 5V-trace between regulator and
module should be at least 2.5mm wide or better an entire layer.

Important:

The module draws up to 1.3A max. for 577µs every 4,6ms at GSM transmit level
PCL5 (2W). Therefore a regulator with fast transient response and good load
regulation is strongly recommended.





Peak 1.3 A