EQ: Capsule Equaliser Setting
Operating Procedure:
1. Press the rotary controller to activate and move the cursor to the EQ parameter. When the EQ
cursor starts to flash, the Equaliser is ready to be set.
2. Rotate the rotary controller clockwise to increase the Equaliser number; counterclockwise to decrease
the Equaliser number.
3. Press the rotary controller once to confirm and save the selected Equaliser number (or wait for auto
save).
8
NOTE:
There are 9 preset and 1 user-defined built-in equalisers (00-09). EQ “00” is the default EQ for the
factory fitted MIPRO handheld microphone capsule. EQ's “01-08” are eight other simulated microphone capsule
presets. EQ “09” is user-defined and can be programmed by the user. However, the receiver needs to be set up
and interfaced with a PC and MIPRO software before this can be achieved.
The EQ parameter is used to select from a range of simulated microphone capsule EQ's. The default
setting for the factory fitted MIPRO capsule is “00”
ADD: Address Setting for PC Remote Control
ADD
GRP
CH
BAND
ANT
MHz ACT
RF
AF
SQ
BA
EQ
ADD cursor starts flashing
Rotate clockwise to increase by one number (01-64)
Rotate counterclockwise to decrease by one number (64-01)
Operating Procedure:
1. Press the rotary controller to activate and move the cursor to the ADD parameter. When the ADD
cursor starts to flash, the Address is ready to be set.
2. Rotate the rotary controller clockwise to increase the Address number; counterclockwise to decrease
the Address number.
3. Press the rotary controller once to confirm and save the selected Address number.
8
NOTE:
This receiver is equipped with an ACT-BUS interface. It allows users to use the MIPRO-DV (interface
converter) and software (sold separately with MIPRO-DV) for remote PC monitoring. It can monitor up to a
maximum of 64 channels at the same time. The receiver module address can be set from 1 to 64. In order to
monitor the system remotely, each channel must have its own address for individual identification. If two or
more channels have been assigned the same address, it will cause confusion in the monitoring system. If the
system is not under PC monitoring/control, identical addresses will not affect the receivers' operation.
For normal “stand-alone” use, this parameter does not need to be set. However when multiple receivers
are to be used and controlled remotely using the MIPRO optional control software each receiver must be
given a unique address. Always ensure that you set this address before adding the receiver to the
remote control network.
8
GRP
CH
BAND
ANT
MHz ACT
RF
AF
BA
EQ
SQ
ADD
EQ cursor starts flashing
Turn clockwise to increase by one number
Turn counterclockwise to decrease by one number
8