EXPANSION INSTRUCTIONS
rev.1, ver.3
1/10
Printed in Canada
www.pathwayconnect.com
Pathway Connectivity Inc., 
#103 - 1439 17 Avenue SE Calgary AB Canada T2G 1J9 
 (403) 243-8110 fax (403) 287-1281 
ESTA
E
NTERTAINMENT
S
ERVICES
&
T
ECHNOLOGY
A
SSOCIATION
Always disconnect main power before removing 
the enclosure’s cover. eDIN Installation Repeaters 
are designed to operate on a mains voltage of 90-
250 volts AC.
RECOMMENDED WIRING PRACTICE
P
OWER
S
UPPLY
:
Universal input (90-250V, 50/60 Hz)
I
NPUT
& O
UTPUT
S
IGNAL
:
USITT DMX512/1990 and E1.11 (DMX512-A) or 
any EIA422/485-based protocol 
D
ATA
C
ONNECTIONS
:
Two piece compression screw terminals, 
16 - 24 AWG 
I
SOLATION
:
2500V opto-isolation input to output
P
ROTECTION
:
Up to 250V AC/DC on all port pins
S
IZE
:
Models 4807/4808 260mm x 509mm x 115mm (10.25” x 13.25” x 4.5”) 
Models 4809/4810 260mm x 509mm x 115mm (10.25” x 23.25” x 4.5”) 
PSU C
ONNECTIONS
Screw-down terminals; 12 –18 AWG
SPECIFICATIONS
DMX TERMINATION
If nothing is connected to the DMX THRU terminal block 
of the final opto-splitter card, then the termination switch 
on this card must be set to the ON position. All the other 
cards are not terminated (switch in the OFF position). 
 
If another card is added, or the signal is passed through 
to another device, the switch on the final card will need to 
be moved to the OFF position and the termination applied 
at the new final device. Always make sure the final re-
ceiving device connected to any output or branch line is 
properly terminated using its internal switch or jumper or if 
necessary a resistor of 120 
Ω
between pins 2 and 3.
INDICATORS
Installation Repeater Installer’s Guide
4807, 4808 
4809, 4810 
DMX WIRING
•
All cabling must be in one continuous run, daisy-
chained: no “Tees” allowed 
•
“Stars” are permitted only in conjunction with a re-
peater or opto-splitter 
•
Cable shield may be earth-grounded at one end only, 
preferably at the control console 
•
Maximum length of one cable segment is 1,800 ft 
(550m) 
•
Receiving devices have male connectors; transmitters 
have female 
•
The last DMX device on the line must be terminated 
with a termination switch or resistor with a value of 
100 to 120 ohms between pin 2 and 3 
•
5 pin XLR connectors are standard:
Pin 1: Common
Pin 2: Data (-)
Pin 3: Data (+)
Pin 4: Optional Data (-)
Pin 5: Optional Data (+)
•
Cable must be Belden 9842 (120
Ω
) 9829, 9729
(100
Ω
) ISO/IEC 11801 (Cat5) or equivalent
•
A maximum of 32 DMX receiving devices can be pre-
sent on a single DMX line 
Keep all DMX cabling away from high voltage/power ca-
bles to maintain data integrity. 
 
Use the appropriate wire for all connections. 
•
DMX Connections: Belden 9829, 9842, Cat5 or 
equivalent. 
•
Power Connections: Insulated #18-16 AWG, stranded 
or solid core 
eDIN Installation Repeaters may hold up to two opto-
splitter cards (model 4807 and 4808) or four cards 
(models 4809 and 4810). If the original enclosure holds 
less than its limit, it is possible to add cards. It’s also pos-
sible to pass through data and low voltage power to a 
second enclosure. 
 
DMX THRU passes the console signal to the additional 
eDIN opto-splitter card, where the wires are connected to 
the DMX IN terminals. While not isolated, DMX THRU 
can also be used to pass signal to other devices. 
 
Power can also be daisy-chained using the second pair of 
V+ and V- terminals. Polarity should be followed at the 
receiving device. 
The face of each card inside the Installation Repeater has 
the following LEDs: 
•
The Power LED will illuminate when power is con-
nected to the card. There is no on/off switch. 
•
The DMX IN LED will illuminate and flicker rapidly 
when DMX data is being received. 
•
Each DMX output has a DMX OUT LED that will illu-
minate and flicker when DMX is being output by that 
branch. 
DMX 512A COMPLIANCE
This product complies with the DMX512-A standard, un-
der the non-compatible connector (NCC) provision. All 
ports are protected to 250V. 
MODEL DESCRIPTIONS
4807
4-way eDIN Installation Repeater
4808
8-way eDIN Installation Repeater
4809
12-way eDIN Installation Repeater
4810
16-way eDIN Installation Repeater