MEGUIAR'S M95 User Manual

Page 5

Advertising
background image

M95, Speed Cut Compound (20-177C): M9501, M9532

__________________________________________________________________________________________

Page: 5 of 15

Select and use gloves and/or protective clothing to prevent skin contact based on the results of an exposure assessment.
Consult with your glove and/or protective clothing manufacturer for selection of appropriate compatible materials.

Respiratory protection

An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of
a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator
type(s) to reduce inhalation exposure:
Half facepiece or full facepiece air-purifying respirator suitable for organic vapours and particulates

For questions about suitability for a specific application, consult with your respirator manufacturer.

SECTION 9: Physical and chemical properties

9.1. Information on basic physical and chemical properties

Physical state

Liquid.

Appearance/Odour

Sweet hydrocarbon odoUr; White, creamy, viscous lotion

pH

8 - 8.8

Boiling point/boiling range

193.3 ºC

Melting point

Not applicable.

Flammability (solid, gas)

Not classified

Explosive properties

Not classified

Oxidising properties

Not classified

Flash point

93.3 ºC [Test Method:Pensky-Martens Closed Cup]
[Details:D93-90]

Autoignition temperature

No data available.

Flammable Limits(LEL)

No data available.

Flammable Limits(UEL)

No data available.

Vapour pressure

No data available.

Relative density

1.02 [Ref Std:WATER=1]

Water solubility

Moderate

Partition coefficient: n-octanol/water

No data available.

Evaporation rate

No data available.

Vapour density

No data available.

Viscosity

25 - 40 Pa-s

Density

1.02 g/cm3

9.2. Other information

Volatile organic compounds (VOC)

11.26 % weight

VOC less H2O & exempt solvents

501.48 g/l

SECTION 10: Stability and reactivity

10.1 Reactivity
This material is considered to be non reactive under normal use conditions

10.2 Chemical stability
Stable.