8.2.1. Engineering controls
Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure
Limits and/or control dust/fume/gas/mist/vapours/spray. If ventilation is not adequate, use respiratory protection equipment.

8.2.2. Personal protective equipment (PPE)

Eye/face protection

The following eye protection(s) are recommended: Safety glasses with side shields.

Skin/hand protection

Gloves made from the following material(s) are recommended: Nitrile rubber.
Polymer laminate

Respiratory protection

Select one of the following approved respirators based on airborne concentration of contaminants and in accordance with
regulations:
Half facepiece air-purifying respirator suitable for organic vapors/acid gases and particulates

SECTION 9: Physical and chemical properties

9.1. Information on basic physical and chemical properties

Physical state

Liquid.

Appearance/Odour

Sweet hydrocarbon odour; White, creamy viscous lotion

pH

8 - 8.8

Boiling point/boiling range

193.3 ºC

Melting point

Not applicable.

Flammability (solid, gas)

Not classified

Explosive properties

Not classified

Oxidising properties

Not classified

Flash point

> 93.3 ºC [Test Method:Closed Cup]

Autoignition temperature

Not applicable.

Flammable Limits(LEL)

Not applicable.

Flammable Limits(UEL)

Not applicable.

Vapour pressure

No data available.

Relative density

1.00 [Ref Std:WATER=1]

Water solubility

Moderate

Partition coefficient: n-octanol/water

No data available.

Evaporation rate

No data available.

Vapour density

> 1

Viscosity

25 - 40 Pa-s

Density

1 g/cm3

9.2. Other information

Volatile organic compounds (VOC)

16.9 % weight

VOC less H2O & exempt solvents

520.73 g/l