Amba Towel Warmers Programmable Timer (Hardwired) User Manual

Installation and user guide, Applications, Installation

Advertising
background image

PLS730B/PLS731B

1/6

PLS730B/PLS731B

Installation and User Guide

Programmable Wall Switch

The PLS730B/PLS731B programmable wall switch has been
designed to control lightings and motors:

NOTE: This switch cannot be used if there are not at least 2 white
wires joined by a connector inside the electrical box.

Cut power at the circuit breaker to avoid electric shock.

Remove the existing switch.

Install the new switch as shown in the diagram below.

Apply power at the circuit breaker.

Pry the switch door open from the
bottom using a small screwdriver.

Ensure the ON/OFF selector is set
to ON.

Reset the switch using a paper clip.
0:00 and MO will flash.

If the display is blank:

Ensure the ON/OFF selector is properly engaged in the ON posi-
tion. Push it to the right using a small screwdriver.

NOTE: The switch displays the time in 24-hour format by default or
following a reset.

To change to 12-hour format (or vice versa), proceed as follows:

a) Press one of the control buttons to ensure the MAN or

AUTO indicator is displayed.

b) Press the MIN and HOUR buttons simultaneously and brief-

tly (0:00 display = 24-hour, 12:00 display = 12-hour ).

Set the time using the HOUR and MIN buttons. If you have
selected the 12-hour format, ensure that PM appears on the
screen when an afternoon time is displayed.

Set the day by using the DAY button.

Press one of the control buttons or close the switch door to
return to normal operation.

The programmable switch has 2 operating modes: manual (MAN)
and automatic (AUTO). To switch mode, press the switch door for 3
seconds.

Manual Mode

The programmable switch operates as a regular
switch. Briefly press the switch door to turn the lights
On or Off. The mode (MAN) and state (ON or OFF)
are displayed.

Automatic Mode

The programmable switch follows the programmed
schedule. The mode (AUTO), state (ON or OFF)
and current program number are displayed.

To temporarily override the programmed schedule,
briefly press the switch door. The new state

(ON or OFF)

will flash to

show that this state is temporary. The override remains in effect until
you press the switch door again or until the beginning of the next
program.

You can set up to 7 programs. To set a program, you need to enter its
start time (ON) and its end time (OFF).

Pry the switch door open using a small screwdriver.

Press the PGM button to display a program and
its On or Off time. For example, when you first
press PGM, program number 1 (P1) and its On
time (ON) will appear. - : - - will appear instead
of the time if the program is not set (inactive).

Press the DAY button to select the day to which
you want to apply the program.
NOTE: If you want to apply the program to
every day of the week, press DAY until all the
days are displayed. (This still counts as 1 program, not 7)

Applications

1.

Load type

Maximum load

Examples

Resistive load

2400 W
(20 A @ 120 V)

incandescent lights

halogen lights

block heater

Inductive load

2400 W
(20 A @ 120 V)

fluorescent lights

compact fluorescent lights (CFL)

sodium lamps

electronic ballasts

Motor

1 hp

pool filter pumps

fans

Installation

2.

Power-On

3.

120 VAC

(line)

white (neutral)

black (line)

blue (load)

Load

Control (4)

Reset

On/Off
selector

Setting the Clock

4.

Selecting the Operating Mode

5.

Programming

6.

69-2503EFS (TI033 Honeywell PLS730B_PLS731B) print at 90%.book Page 1 Wednesday, September 29, 2010 4:11 PM

Advertising