Minka Group F707-FLP User Manual
Page 13

Fig.13
Fig.12
Fig.14
Fig.15
RECEIVER
OUT LET
BOX
RECEIVER
FAN
RECEIVER
OUTLET BOX
WALL CONTROL
GROUND
GREE
N
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
WHITE
WHITE
BLUE
BLUE
BLACK
WHITE
Step 4.If your outlet box has a GROUND wire (Green
or Bare Copper) connect this wire to the Hanger Ball
and Hanger Bracket Ground wires. If your outlet box
does not have a Ground Wire, then connect the Hanger
Ball and Hanger Bracket Ground Wires together. Secure
wire connection with the plastic wire nut provided.
(Fig. 14 & 15)
After all splices are made, check to make sure there
are no loose strands. As an additional precaution w
suggest to secure the plastic wire
connectors to the wires with electrical tape.
Note: Fan must be installed from a maximum distance
of 40 feet from the transmitting unit for proper signal
transmission between the transmitting unit and the
fan's receiving unit.