Seal-chamber cover removal – Goulds Pumps 3198 i-FRAME - IOM User Manual

Page 69

Advertising
background image

Shaft Wrench

101

4. Repeat step 3 until the impeller becomes loose.
5. Remove and discard the impeller O-ring (412A).

You will insert a new O-ring during reassembly.

412A

Figure 16: O-ring for models 3196, HT 3196, NM 3196, 3198, and 3796

If the impeller cannot be removed by the previous methods, cut the shaft between the gland and the
frame, remove the impeller, stuffing-box cover, gland, sleeve, and shaft end as a unit. Do not apply heat.

Seal-chamber cover removal

Seal-chamber removal procedures

Choose from one of these procedures to remove the seal-chamber cover.

Table 9: Procedures for seal-chamber cover removal by model

Model

Procedure

3196, CV 3196, HT 3196, LF 3196, 3796

Remove the seal-chamber cover.

NM 3196, 3198

Remove the seal-chamber cover and/or backplate.

Remove the seal-chamber cover and backplate (NM 3196, 3198)

1. Remove the gland nuts or seal-chamber stud nuts (355).
2. Remove the backplate stud nuts (370H).
3. Remove the backplate (184).

Maintenance

Model 3198 i-FRAME Installation, Operation, and Maintenance Manual

67