7.6.1 Tightening torques


Size 2x3-7

No. of stages

≤ 12

13 - 15

16 - 18

Tightening
torque

710 Nm 850 Nm 900 Nm


Size 2.5x4-8

No. of stages

≤ 8

9 - 13

14 - 18

Tightening
torque

610 Nm 920 Nm 980 Nm


Size 4x5-11

No. of stages

≤ 4

5 - 8

9 - 12

13 - 15

Tightening
torque

790 Nm 1420 Nm 1570 Nm 1790 Nm


7.6.2 Pump assembly


- Installation starts on the suction side.
- The pump should be assembled in a vertical position, if

possible.

- Install the parts in their original position.
- Observe the sectional drawing with list of components.
- Lightly tighten the nuts of the tie bolts.
- Place pump on its feet, in horizontal position, on a flat

work surface.

- Tighten nuts of the tie bolts in several stages in

diagonal sequence (nominal tightening torque at last
stage).


7.6.2.1.

Shaft seal



Packed stuffing box

CAUTION

• The packing rings must not be inserted until after the

pump, including the bearings, has been completely
installed.



- Only pre-compressed packing rings are permissible.
- Thoroughly clean the packing area and the stuffing box

gland.

- The first packing ring should now be laterally bent

open and pushed on the shaft wearing sleeve.

- Slide the packing ring into the packing chamber using

the stuffing box gland.

- Install the other packing rings in the same manner,

however with the gaps 180° apart.

- Turn the gland nuts finger-tight.
- Check that the gland is not tightened at a slant.

CAUTION

• The pump rotating assembly must be free to rotate by

hand.

• The stuffing box leakage must not be adjusted until

start-up (see Section 6).



Dimensions Pump

size

in mm

2x3-7

2.5x4-8 4x5-11

Packing cross-section

10

10

12.5

Number of rings

4

5

Shaft diameter

45

75

95



Mechanical seals

CAUTION

• Utmost care should be taken when mounting the

rotary and stationary seal rings so as to avoid
contamination and/or distortion on the sealing
surfaces.

• EPDM seals must not be exposed to oil or grease.

• In order to achieve the compression pressure required

for the operational reliability of the mechanical seal,
check the axial installation dimension against the
installation drawing.



- Install the mechanical seal in the reverse manner to

disassembling.