WARNING

Allow all system and pump components to cool
before handling them to prevent physical injury.

3.

Disconnect all auxiliary piping and tubing.

4.

Remove coupling guard. Refer to Coupling Guard
Installation and Disassembly Section in Appendix II.

5.

Disconnect Coupling.

NOTE: Refer to Appendix V for C-Face adapter
disassembly instructions, if required.

6.

Remove coupling guard pump endplate.

7.

If oil lubricated, drain oil from bearing frame by
removing bearing frame drain plug (408A).
Replace plug after oil is drained. Remove oil
reservoir, if equipped (Fig. 40).

NOTE: Oil analysis should be part of a
preventive maintenance program and is helpful
to determine cause of a failure. Save oil in a
clean container for inspection.

8.

All, except with C-Face adapter: Place sling from
hoist through frame adapter (108) or frame (228A)
for STX (Fig. 41).

C-Face adapter: Place one sling from hoist
through frame adapter (108) or frame (228A) for
STX and a second sling from hoist through the
C-Face adapter (Fig. 42).

9.Remove bearing frame foot hold down bolts.

10. Remove casing bolts (370).

s

!

WARNING

Never apply heat to remove parts. Use of heat
may cause an explosion due to trapped fluid,
resulting in severe physical injury and property
damage.

11. Remove back pull-out assembly from casing

(100). Tighten jack screws (418) evenly to remove
back pull-out assembly (Fig. 43).

NOTE: Penetrating oil can be used if adapter to
casing joint is excessively corroded.

NOTE: Remove and then mark shims from
under frame foot. Save for reassembly.

56

ANSIFAM IOM - 5/08

Fig. 40

Fig. 41

Fig. 43

Fig. 42

Advertising