Goulds Pumps ANSI FAMILY IOM (ATEX Compliant) User Manual

Page 22

Advertising
background image

2.

Spread bottom of coupling guard half (pump end)
slightly and place over pump end plate as shown
in Fig. II-4. The annular groove in the guard half
is located around the end plate (Fig. II-5).

3.

After the coupling guard half (pump end) is
located around the end plate, secure it with a bolt,
nut and two (2) washers through the round hole at
the front end of the guard half as shown in Fig.
II-6. Tighten securely (Fig. II-7).

4.

Spread bottom of coupling guard half (driver end)
slightly and place over coupling guard half (pump
end) so that annular groove in coupling guard half
(driver end) faces the motor as shown in Fig. II-8.

124

ANSIFAM IOM - 5/08

Fig. II-5

ANNULAR GROOVE

234A

501B

Fig. II-6

Fig. II-4

501B

ANNULAR
GROOVE

DRIVER

234A

Fig. II-7

NUT

WASHER

BOLT

Fig. II-8

ANNULAR

GROOVE

501B

DRIVER