Goulds Pumps Pump Safety User Manual

Page 5

Advertising
background image

S-5

General Precautions

WARNING



Alignment:
Shaft alignment procedures must be followed to prevent catastrophic failure of drive
components or unintended contact of rotating parts. Follow coupling manufacturer’s
coupling installation and operation procedures.

WARNING



Before beginning any alignment procedure, make sure driver power is locked out. Failure
to lock out driver power will result in serious physical injury.

CAUTION



Piping:
Never draw piping into place by forcing at the flanged connections of the pump. This may
impose dangerous strains on the unit and cause misalignment between pump and driver.
Pipe strain will adversely effect the operation of the pump resulting in physical injury and
damage to the equipment.

WARNING

Flanged Connections:
Use only fasteners of the proper size and material.

WARNING

Replace all corroded fasteners.

WARNING

Ensure all fasteners are properly tightened and there are no missing fasteners.

WARNING



Startup and Operation:
When installing in a potentially explosive environment, please ensure that the motor is
properly certified.

WARNING



Operating pump in reverse rotation may result in contact of metal parts, heat generation,
and breach of containment.

WARNING



Lock out driver power to prevent accidental start-up and physical injury.

WARNING



The impeller clearance setting procedure must be followed. Improperly setting the
clearance or not following any of the proper procedures can result in sparks, unexpected
heat generation and equipment damage.

WARNING



If using a cartridge mechanical seal, the centering clips must be installed and set screws
loosened prior to setting impeller clearance. Failure to do so could result in sparks, heat
generation, and mechanical seal damage.

WARNING



The coupling used in an ATEX classified environment must be properly certified and
must be constructed from a non-sparking material.

WARNING

Never operate a pump without coupling guard properly installed. Personal injury will
occur if pump is run without coupling guard.

WARNING



Make sure to properly lubricate the bearings. Failure to do so may result in excess heat
generation, sparks, and / or premature failure.

CAUTION



The mechanical seal used in an ATEX classified environment must be properly certified.
Prior to start up, ensure all points of potential leakage of process fluid to the work
environment are closed.

Advertising