FIGURE 2 - Pump only Installed

Pump and motor installed:
Remove the straps that hold the
ChemBasePlus™ to the wooden pallet. Install
a sling around the pump suction nozzle and
around the outboard end of the motor frame
using choker hitches pulled firmly

tight as shown in Figure 3. The motor sling
should be positioned so the weight is not
carried through the motor fan housing.

FIGURE 3 - Pump and motor installed

SECTION 4.0 – INSTALLATION

4.1 GENERAL DESCRIPTION OF THE

ChemBasePlus

The Goulds ChemBasePlus™ is a solid
polymer composite baseplate that is
manufactured to conform to ASME/ANSI
B73.1M-1991 and custom versions. The
Goulds ChemBasePlus™ has been designed
to provide a solid and rigid foundation under
the pump and its respective motor, whereby,
serving the purpose of maintaining sound
alignment between them.
The ChemBasePlus™ has been made
available in two basic types:

Foundation mounted (grouted in
design – Figure 4)

FIGURE 4 – Foundation Mounted