Installation, Operating and Maintenance Instruction

Model ICP


ICP 100-English

page 18

Revision 00

Article No 24264412

Issue

05/2006

pic 13

ƒ Loosen hexagen head bolt (901.41). Remove the

bearing bracket lantern from bearing bracket
(330).

ƒ Dismount circlip (932.51). Therefore you need a

snap ring plier acc. to DIN 5256-C.

Bearing

bracket

required snap ring

plier

length i (min.) of

snap ring plier

24

size 94/C 40

200mm

32, 42

size 94/C 85

250mm

48

Größe 94/C 85

300mm

ƒ Remove shaft (210) including anti-friction bearing

(320.51 and 320.52) and bearing nut (923.51)
from the bearing bracket (330).

ƒ Remove the bearing nut (923.51). The bearing nut

is right hand threaded and self locking. It can be
reused 5 times if it is handled appropriately.

ƒ Remove the anti-friction bearing (320.51 and

320.52) from the shaft (210) using a hydraulic
press or a bearing puller.

8.7 Reconditioning

After disassembly all parts must be cleaned and
checked for wear carefully. Worn or damaged parts
must be replaced by new parts (spare parts).
When reassembling the pump it is recommended to
replace all seals.

All PTFE-sealing elements and graphite seal-
ings are intended for being used only once.

In most cases it make sense, if damaged absolutely
necessary, to renew the mechanical seal and the
bearings.
Deposits on the impeller (230), in the volute casing
(102V) or on the casing cover must be removed.




8.7.1 Clearance at impeller

Suction side of impeller

Back vanes of impeller

Drive side of impeller

Only for pump sizes
100-65-315
125-80-315
125-80-400
125-100-315
125-100-400
150-125-315
150-125-400
200-150-315
200-150-400

Nominal diameter D (mm)

60
68

85

100
120
135

155
175

220

min.

0,15 0,17 0,20 0,22

0,25

new

max.

0,19 0,22 0,24 0,27

0,30

Radial
clearance s
(mm)

wear limits

0,78 0,85 0,90 1,05

1,15

new

0,8 - 1,2

Axial
clearance a
(mm)

wear limits

max. 1,7

When the wear limits has been reached or ex-
ceeded, the worn parts must be replaced.

For volute casings (102V) with a wear ring (502.11)
and cover casings (161) with a wear ring (502.31)
there are the following possibilities to restore the cor-
rect clearance:
a) Renew impeller (230) and wear ring. Then the

original measures are restored.

b) A customized wear ring (bored to fit) can be sup-

plied to avoid replacement of the impeller. Please
contact factory for details.

When volute casing (102V) or casing cover (161)
without wear ring must be repaired, a wear ring can
be installed to renew pump performance. Remachin-
ing of the volute casing and /or casing cover is re-
quired. Please contact the factory for details and as-
sistance.

8.8 Mounting

Re-assemble the pumps using the reverse order of
steps as completed for pump disassembly. However
the following observations should be considered:
ƒ Pay attention to the utmost cleanliness when re-

assembling the pump.

ƒ For tight tolerances, e.g. between shaft sleeve

(433) and shaft (210) or impeller (230) and shaft
(210), as well as thread, use a suitable anti-galling
compound (e.g. Molykote/Never-Seeze), so that
the assembly and the next disassembly will be
easier.

Anti-galling compound must be compatible with
the pumpage.