The Mug Froster/Plate Chiller is designed to chill mugs, glasses, plates, etc. that will appear “frosted” when removed. The

operating temperature range of 0°F (-18°C) to 35°F (2°C).

The Mug Froster/Plate Chiller should be filled with dry, room-temperature mugs, glasses, plates, etc. to allow maximum

chilling. During business hours, the Mug Froster/Plate Chiller can be loaded with additional dry, room-temperature mugs,

glasses, plates, etc. Allow 30 minutes for chilling.

Defrost instruction for Mug Frosters manufactured prior to 03-03-2014 with SN prior to 404149308:

• The Mug Froster/Plate Chiller includes an automatic defrost system. Defrosting will occur every six hours for

approximately 20 minutes. During the defrost cycle, the fan inside the Mug Froster/Plate Chiller will turn off and a

small amount of mist may appear if the top is opened.

• There is also a manual defrost system controlled by a switch located on the front left bottom of the Mug Froster/Plate

Chiller. This is used when there is ice or snow accumulation inside. An end-of-the-day or weekly schedule can be

established for the activation of this manual defrost cycle.

• When the manual defrost switch is pushed, a light will turn on and the Mug Froster/Plate Chiller will go into a six-hour

defrost. After six hours, the Mug Froster/Plate Chiller will resume normal operation.

• If the manual defrost switch is accidentally pushed, the defrost cycle can be terminated by unplugging the power

cord for three seconds.

Defrost instruction for Mug Frosters manufactured on and after 03-03-2014 with SN 404149308 and after:

Mug Froster Elan Digital Control Operations

Control Display

• Normal Operation- Actual box temperature is displayed and the Power LED is illuminated. The compressor LED

will be illuminated when the compressor is running.

• Defrost Operation- During normal defrost operation, the Setpoint temperature will be displayed and the Defrost

LED will be illuminated. During the Manual 6 hour defrost operation, the 6hr LED and the Defrost LED will be

illuminated. The display will show the time remaining in the 6 hour cycle.

Temp Adjustment

• Setpoint Min.

0 deg F

• Setpoint Max

35 deg F

• Setpoint Default 10 deg F

• Differential

+8 deg F

• Changing Setpoint- Press the up or down arrow key to raise or lower the setpoint in 1 degree increments.

• Temp Recall- To recall the temperature set point, press the RCL key one time. The display will show Set for 3

seconds then the setpoint temp for 3 Seconds. The control then returns to actual box temp.

o

Peration

and

C

leaning