SYNC Messages
Problem / Remedy
WRONG DEVICE
•
Transmitter frequency band does not match the receiver’s frequency band.
ERROR DEVICE
•
Error in transmitter ID data.
-
If the problem occurs frequently, contact your AKG Service Center.
TIMEOUT
•
No infrared data detected.
27
11 Troubleshooting
DMS
700
Status/Error/Warning Message
Problem / Remedy
ENCRYPTION! (cont’d)
-
Check transmitter frequencies.
•
RF input power too high.
-
Use CLA switch bank on the PS 4000 W to reduce the RF signal level. Refer to
section 3.6 in the PS 4000 W user manual or visit www.akg. com (DMS 700
Multichannel System Setup Guide).
BDA_DMS 700_D030926_4China 12/09/2009 16:31 Seite 27 (Schwarz/Black Auszug)