Installation of indoor unit, Refrigerant line installation, Piping and insulating – Comfort-Aire B-VFH18MA-1 User Manual

Page 20

Advertising
background image

20

VFH InverterFlex

®

- Indoor Ductless Mini-Split

Heat Controller

4. Refrigerant Line Installation

A. Remove the knockout from the desired side of the

unit that the line set will be routed from. The lines

from the unit can be routed either left or right, left

back or right back (Fig. 11).

B. Loosely run the line set connections from the in-

door unit through the hole in the wall (Fig. 8).

C. Hang the unit onto the top flanges of the wall

bracket. Ensure the unit is properly seated. (Fig.

12)

D. Keep the unit away from the wall to prevent the

line set from being kinked or crushed, use a piece

of styrofoam as a spacer between the back of the

unit and the wall. (Fig. 13)

E. Feed the condensate drain line and refrigerant line

set through the hole such that the unit can sit flush

against the wall then remove the spacer (Fig. 8).

F. Push the bottom of the unit up and onto the lower

flanges of the wall bracket. Ensure that unit is

properly sealed.

G. Be sure that the overall installation of the indoor

unit and installation plate are flush against the wall

and level.

5. Piping and insulating

A. Bundle the tubing, connecting cable, and drain hose

with tape or wire ties as shown in (Fig.14).

B. Be sure to arrange the drain line such that it is at

the lowest point within the bundle as they exit the

unit and hole in the wall to the outdoors. (Fig. 14)

C. Because the condensed water from rear of the

indoor unit is gathered in the ponding. Do not put

anything else in this area.

E. Insulate the liquid line and suction lines separately.

ATTeNTIoN: See outdoor installation instructions

for line set and charging information and

installation instructions.

Fig. 12

Fig. 13

Spacer

Top Flange

Bottom Flange

Ponding box

Tape/wire tie

Line set

Drain line

Connecting

Cable

Fig. 14

Fig. 11

Right

Knockout

Knockout

Right back

Left Back

Left

Indoor Unit

Installation of Indoor Unit

Advertising
This manual is related to the following products: