INSTALLATION INSTRUCTIONS

10

Please read ALL instructions before installing. Two people are recommend to install this product.
If a new electrical outlet is required, have the outlet installed by a qualified electrician before

installing unit.

Preliminar y Instr uctions

Do the following before starting to install unit.
See illustrations below.

Check dimensions of your unit to determine
model type:
Unit Height:
Unit Width:
Min. Window Opening:
Min. Window Width:
Max. Window Width:

18 5/8

17 5/8

26

23

1

2

/

1

2

/

19

18

1

2

/

31

26

1

2

/

43

40

1

2

/

1.

-- the mounting

parts furnished with this air conditioner are
made to install in a wooden sill double-hung

window. The standard parts are for window
dimensions listed above. Open sash to a mini-
mum of 19 inches(483mm). See Fig.1.

Check window opening size

2.

-- all wood parts of

window must be in good shape and able to firmly
hold the needed screws. If not, make repairs
before installing unit.

Check condition of window

3.

-- if your storm

window frame does not allow the clearance
required, correct by adding a piece of wood as
shown in FIG. 2,or by removing storm window
while room air conditioner is being installed.

Check your storm windows

4 .

--

check area outside of window for things such as
shrubs, trees, or awnings. Inside, be sure
furniture, drapes, or blinds will not stop proper
airflow.

Check for anything that could block airflow

5.

Power

supply must be the same as that shown on the
unit serial nameplate. Power cord is 48 inches
long. Be sure you have an outlet near.

6.

Remove all

packing material. Protect floor or carpet from
damage. Two people should be used to move
and install unit.

Check the available electrical service-

Carefully unpack air conditioner-

SASH

/2 MIN.

1

19 MIN.

Storm Window Frame or
Other Obstruction

Storm Window
Frame or Other
Obstruction

Board
Thickness
As Required,
Along Entire
Stool. Fasten
With Two Nails
Or Screws.

Fig.1

Fig.2

/2 MIN.

1

/2 MIN.

1

19 MIN.

SASH

Window Sash Seal

Safety Lock and
3 /4 Long Hex
Head Screw

Top Angle

Foam Gasket

Washer Head

Locking screw

Frame

Assembly

(Left)

Side Retainer

Seal-bottom

Rail to Unit

1 /2 Long

Screw and

Locknuts

Locknut

3 /4 Long

Flat Head

Bolt

Sill Angle

Bracket

Window Support

Bracket

Frame

Assembly

(Right)