Installation instructions, Complete installation, Option 2 plastered wall with no molding – Comfort-Aire REG-123G User Manual

Page 15: Install wood frame

Advertising
background image

Heat Controller, Inc.

Room Air Conditioner with R-410A

Owner’s Manual

14

14

INSTALLATION INSTRUCTIONS

A

A B C

D

A. Molding

B. Inside wall

C. Wood frame

D. Louvers

AB C

D

C. Wood frame

D. Louvers

FIG.15

FIG.18

FIG.19

B

C

D

A

B

C

C

D

FIG.20

FIG.16

FIG.17

C. Wood thickness

A. Window lock bracket

B. Upper window glass

C. Window sash seal

D. #10X3/4 round-head

screws

Complete Installation:

1. Insert window sash seal behind the top of the lower window sash and

against the glass of the upper window (FIG.15).

2. Place the window-lock bracket on top of lower window and against upper

window sash on right side of the window (FIG.15).

3. Use a 3/32 drill bit to drill starter holes through the holes in the bracket

into the window sash (FIG.15).

4. Attach the window lock-bracket to the window sash with two #10 X 3/4

round-head screws to secure window in place (FIG.15).

5. Insert air conditioner into cabinet (FIG.16).

6. Insert front tabs of front panel into top of cabinet and swing front into place.

7. Attach bottom front of panel with front panel screws (FIG.17).

8. Plug into a grounded 3 prong outlet.

9. Press RESET on the power supply cord.

Through-the-Wall Cabinet Installation:

Option 1 wood, metal or plastic molding:

When using a wood, metal or plastic molding, the wood frame should line up with the inside wall as

shown FIG.18

Option 2 Plastered wall with no molding:

If the plastered wall is to be flush with the cabinet and no molding is used, the wood frame must be set

1/2 (13mm) into the inside wall FIG.19.

Install Wood Frame:

1. Construct the wood frame. See FIG.20 for dimensions.

2. Measure the outside width and height of frame to determine wall opening dimensions. The wall

opening measurements should be :

A. Plastered wall

B. Inside wall

Width : 22-5/8 (57.5 cm) plus twice thickness of wood used to build frame.

Height: 16 (40.6 cm) plus twice thickness of wood used to build frame.

Depth : 2-1/2 (6.4 cm) minimum to 6-1/2 (16.5 cm) maximum.

3. Cut the opening through the wall. Remove and save insulation.

4. Apply the wood preservative to the outside exposed surface.

5. Insert the frame in the wall opening. Square and level frame.

6. Attach frame securely to the wall.

Plug into a grounded 3 prong outlet rated for proper voltage according to unit’s nameplate.