Applications
Air Handlers can be applied in upfl ow, downfl ow, horizontal
right and horizontal left applications without modifi cations. For
horizontal applications, installation of an auxiliary/secondary
drain pan is required.

CAUTION!

CAUTION! For horizontal applications, the horizontal drain pan
must be located under the indoor coil. Failure to place the pan
under the coil can result in property damage.

Installation

5HWXUQ

'LVFKDUJH

TOP

DISCHARGE

5HWXUQ

'LVFKDUJH

1” to 2” Filter Rack Conversion
The unit is shipped with1” fi lter rack from the factory. The conversion
process is assumed that the unit is in upfl ow confi guration.

1. Place unit on a fl at surface. Remove 2 knurled thumb knobs that

secure the fi lter rack door at the bottom of the unit.

2. Remove 3 screws that secure the lower fi lter tracks on each side

of the unit.

3. Lift and rotate the fi lter tracks upside down and reinstall fi lter

tracks and screws back.

4. Replace the fi lter rack door and the 2 knurled thumb knobs.