FIGURE 24

FACTORY SET BLOWER SPEEDS

MODEL

PSC MOTOR

COOL

HEAT

COOL

HEAT

X-13 MOTOR

2.0 TON W/40K HEAT

HIGH

LOW

HIGH (Tap 3)

DEDICATED (Tap 1)

2.0 TON W/60K HEAT

HIGH

HEAT

HIGH (Tap 3)

DEDICATED (Tap 1)

2.0 TON W/80K HEAT

HIGH

HEAT

HIGH (Tap 3)

DEDICATED (Tap 1)

2.5 TON ALL HEAT INPUTS

LOW

LOW

HIGH (Tap 3)

DEDICATED (Tap 1)

3.0 TON ALL HEAT INPUTS

MED

LOW

HIGH (Tap 3)

DEDICATED (Tap 1)

3.5 TON ALL HEAT INPUTS

HIGH

LOW

HIGH (Tap 3)

DEDICATED (Tap 1)

4.0 TON ALL HEAT INPUTS

HIGH

LOW

HIGH (Tap 3)

DEDICATED (Tap 1)

1st Stage - DEDICATED (Tap 2)

DEDICATED (Tap 1)

5.0 TON ALL HEAT INPUTS

N/A

N/A

2nd Stage - HIGH (Tap 4)

*460 volt units: Do not adjust from factory speed.

3. Cooling speeds can be adjusted as noted in Figure 23 by moving appropriate wire

between taps at the blower (Do not connect wires to unspecified speed taps).

Note: Heat speed is dedicated and should not be changed. The first stage cooling
speed on 5-ton models is dedicated and should not be changed.

4. Replace blower access panel.