Other settings, Multi-dimensional movement – RMS Technologies 4-AXIS CONTROLLER/DRIVER User Manual

Page 29

Advertising
background image

S I X P A C K / Q U A D P A C K

29

Function of the ready Output

The ready output can be activated (low, open collector), whenever a motor is active (velocity greater
than 0) or search of reference. The ready output will be switched within 2 ms after start/end motor
movement. The repeatability (jitter) equals approximately the microstep rate during start respectively
stop (s. CMD $13).

CMD

$33

P0

mask for active motors (bit 0=motor 0, bit 5=motor 5)

P1

mask for reference search of a motor (bit 0=motor 0, bit 5=motor 5)

8.6 Other

Settings

Adjust RS 232 / RS 485 Baud rate

CMD

$40

P0,P1 #

baud rate divisor (16 bit): baud rate divisor=20MHz/ (16*baud rate)

P2,P3 #

transmitter switch on/off delay time in increments of 2ms (1..1000)

(default: 6ms)

Setting of Timeout for Abort of Packet (RS 232 / RS 485)

CMD

$41

P0,P1 #

timeout in increments of 2ms (2..65535)

Change Address of Unit (RS 232 / RS 485)

CMD

$42

P0

new RS 232 / RS 485 address

Read out Information about Unit

Allows to read out of firmware revision, reset-flag, temperature and serial number.

CMD

$43

P0 response

address

response
CMD $43
P0

firmware-revision (e.g. 148=V1.4.8)

P1

reset flag: during first read out 1, afterwards 0

P2

temperature of PACK in °C (8 bit signed)

P3,P4 #

serial number

Configure /query RS 232-operating Mode via CAN

CMD

$44

P0 response

address

P1

response address for RS 232-receiving via CAN (upper 8 bit)

P2

number of bytes which should be forwarded with RS 232-receiving (1..8, 0=disabled)

Response
CMD $44
P0

number of bytes in the RS 232-send buffer (0=empty)

P1

bit 0: State of the CTS line (inverted)

Advertising