E. COMPRESSED AIR SUPPLY SYSTEM
A clean, dry, regulated air supply of 80 PSI (5.51 bars) compressed air must be supplied to the dryer. The
connection size is 1/8-inch N.P.T. No air filtering or pressure regulating devices are provided with the standard
ML-200 Non-Tilt dryer.
1. Gas Dryers
The air line supply connection is made into the 1/8-inch N.P.T. port on the air jet solenoid valve which is
located in the base of the dryer. (Refer to the illustration below.)
2. Steam Dryers
The air line supply connection is made into the 1/8-inch N.P.T. tee which is located at the left hand side
of the top of the dryer. (Refer to the illustration below.)