Heater Installation

HEATER LOCATION AND

CLEARANCES

the heater is intended for use

located on a hard floor, table top,

desk or on shelf, and the like, or

suspended on a wall or ceiling

by means of provided hanger

bracket.
When suspended from wall or

ceiling heater should be located

along outside walls to provide

perimeter air circulation.
the discharge air should wipe the

walls without blowing directly on

them. (Figure 2)
If heater is to be tilted on

horizontal axis after mounting -

ensure a minimum clearance of

26.5 inches (67 cm) between floor

and bottom of heater. also, when

mounted to ceiling, ensure a

minimum clearance of 3.5 inches

(9 cm) from ceiling to top of

heater. Ensure the air discharge

is parallel to or away from walls.
INSTALLATION WITH WALL/

CEILINg HANgER BRACkET

!

NOTE:

to prevent personal

injury always use a licensed

electrician to install new outlets or

circuits.

DISCHARGE

OUTSIDE WALL

Figure 2

the use of the hanger bracket

allows the unit to be rotated

approx 45 degrees in each

direction from centre, when

attached to wall and tilted in 45

degrees range while suspended

from a wall or ceiling.

!

NOTE:

the hardware for

mounting the hanger bracket to

the wall or ceiling is not included.

CAUTION:

When turning

and/or tilting the heater do not

block the exhaust opening.
the following steps are shown in

Figure 3.

Locate a stud or other

1.

suitable support and install

hanger bracket on wall or

ceiling. select location so

control knob on back of

heater will be reached easily.