Chemglass CG-1994 User Manual

Page 3

Advertising
background image

3

Optimag 082011

Page

Safety instructions

3

Unpacking

5

Correct use

5

Operation

5

Setting the operating mode

6

Setting the safety temperature limit for

6

Setting the temperature control mode for

6

Assembling the stand

7

Maintenance

7

Error codes

8

Technical data

9

Accessories

10

Warranty

10

For your protection

• Read the operating instructions in full before starting up and

follow the safety instructions.

• Keep the operating instructions in a place where they can be

accessed by everyone.

• Ensure that only trained staff work with the appliance.
• Follow the safety instructions, guidelines, occupational health

and safety and accident prevention regulations.

• Socket must be earthed (protective ground contact).
• Caution - Magnetism! Effects of the magnetic field have to be

taken into account (e.g. data storage media, cardiac pacemakers ...).

• Risk of burns! Exercise caution when touching the housing parts and

the heating plate. The heating plate can reach temperatures in excess
of 310 °C. Pay attention to the residual heat after switching off.

• Ensure that the mains power supply cable does not touch the

heating base plate.

• Wear your personal protective equipment in accordance with the

hazard category of the media to be processed. Otherwise there
is a risk from:
- splashing and evaporation of liquids
- ejection of parts
- release of toxic or combustable gases.

• Set up the appliance in a spacious area on an even, stable, clean,

non-slip, dry and fireproof surface.

• The feet of the appliance must be clean and undamaged.
• Check the appliance and accessories beforehand for damage

each time you use them. Do not use damaged components.

• Gradually increase the speed.
• Reduce the speed if

- the medium splashes out of the vessel because the speed is too high
- the appliance is not running smoothly
- the container moves on the base plate.

• Caution! Only process and heat up any media that has a flash

point higher than the adjusted safe temperature limit that has
been set (50 to 360 °C).
The safe temperature limit must always be set to at least 25 °C
lower than the fire point of the media used.

• Beware of hazards due to:

- flammable materials
- combustible media with a low boiling temperature
- glass breakage
- incorrect container size
- overfilling of media
- unsafe condition of container.

• The appliance may heat up when in use.
• The base plate can heat up due to the action of the drive magnets

at high motor speeds, even if the heater is not operational.

• Process pathogenic materials only in closed vessels under a suit-

able extractor hood. Please contact Chemglass if you have any
questions.

• Do not operate the appliance in explosive atmospheres, with

hazardous substances or under water.

Contents