795-92794 04-13 Air Motor Mixer OMI

2

AIR MOTOR GENERAL INFORMATION

The air motor is designed to be driven by

compressed air and under NO circumstances to

be driven by any other gases. The air motor must

not be driven by fluids, particles, solids or any

substance mixed with air, particularly combustible

or flammable substances likely to cause explosions.

Do not run mixer air motor with flammable or

explosive gases or operate the unit in an

atmosphere containing them.

The air motor is designed for compressed air

only. Do not allow corrosive gases or particulate

material to enter the motor. Water vapor, oil-based

contaminates, or other liquids must be filtered out.
EYE PROTECTION IS REQUIRED. Keep face away

from exhaust port.

PRODUCT USE CRITERIA

Normal conditions:

Operate mixer at temperatures up to 250°F

(121°C).
• Protect air motor from dirt and moisture.

• Use ONLY compressed air to drive air motor.

• Air lines connected to air motor should be the same size

or the next size larger than the inlet port for efficient output

and speed control.

• Protect all surrounding items from exhaust air to avoid oily

build-up on components.

• Bearings are grease packed. No maintenance is required.

• Use a detergent SAE#10 automotive engine oil for lubricat-

ing.

SAFETY INSTRUCTIONS

When mixing flammable or combustible materials,

a Static Protection Kit must be used. Order

Graymills Part No. 790-100835.

• Improper environment, installation and operation can result

in severe personal injury and/or damage to property.

Qualified personnel must perform all work to assemble,

When using mixer, be aware of what liquid is/has been

mixed previously. If liquid is potentially harmful, take ap-

propriate precautions, including wearing personal protec-

tive clothing.

• Read and follow all safety instructions supplied with the

fluids/inks you will be mixing.

• This mixer has rotating parts. Use caution.

• Air motor must have filtered and lubricated compressed air.

For proper operation, maintain the correct air volume and

do not exceed 100 PSI (7 bar).

• Be sure all fittings and connections are properly tightened

before use.

• Shut off and then remove air supply before doing any service

on mixer or motor.

• Wear eye protection and appropriate safety gear when us-

ing mixer.

• Do not operate mixer or allow others to operate mixer

until the instructions and warnings have been read and are

understood by all people involved.

Never work with equipment you feel may be

unsafe. Contact your Supervisor immediately.
• Check the site to make sure that the air motor will be ad-

equately ventilated and that there is no external heat input.

The cooling air may not exceed 104°F/40°C.

• Check that the air motor is not damaged.

INSTALLATION AND OPERATION

Correct installation is your responsibility. Make sure you have

the proper installation conditions. Contact Graymills Customer

Service (773-248-6825) if you have any questions.

• Check the site environment for potentially explosive oils,

acids, gases, vapors or radiation.

Improper environment, installation and operation can result

in severe personal injury and/or damage to property.

• Qualified personnel must perform all work to assemble,

install, operate, maintain and repair air motor.

• Follow these instructions and the warning and information

labels on the motor and all other drive configuration docu-

ments, startup instructions and circuit diagrams.

• Follow all current applicable national and regional specifi-

cations regarding explosion protection, safety and accident

prevention.

• Check the ambient temperature of the site and the ability to

maintain proper ambient temperature.

• Air stream from product may contain solid or liquid materi-

als that can result in eye or skin damage.

• Wear hearing protection as needed. Sound level from mo-

tor may exceed 85 db(A).

• Failure to follow these instructions can result in eye injury

or other serious injury.

Place mixer in liquid before starting.

• Make sure mixer is firmly attached to container before

starting.

We recommend that you obtain the Graymills lid

made specifically for this mixer system.

• Do not attach air line until mixer is in fluid and you are

ready to begin mixing.

• Operator should wear eye protection (and appropriate

personal protective clothing).

• Do not use mixer with liquids containing solids that could

damage propellers or motor.

• Ensure unit has adequate access to airflow for motor cool-

ing.

1. Mixer is assembled except for mounting hardware.

2. Remove propeller if necessary to insert shaft through tank

lid.

3. Reattach propeller and tighten locking set screw when in

place.

4. Immerse mixer propeller in liquid to be mixed, ensuring it is

submerged sufficiently to prevent splashing.

5. Secure motor mounting plate to tank lid.

6. Connect lines to motor in the proper direction.

Advertising