Installation Directions

Prepare Strike

5. Choose the appropriate faceplate for the strike as

illustrated in Diagram 5 on page 3.

6. Connect wires from the power source to the strike.

7. Install the electric strike unit in jamb cutout, using

#12-24 x 1/2” Mounting Screws provided.

8. If horizontal adjustment is needed, see Diagram 6

on page 3.

CAUTION! Before connecting any device at the installation site, verify input voltage using a multimeter.

Many power supplies and low voltage transformers operate at higher levels than listed. Any input voltage exceeding

10% of the solenoid rating may cause severe damage to the unit and will void the warranty.

Finish Installing

3

Installation Diagrams

LBM WIRING

White

Orange

Normally Open

Green

Normally Closed

Common

LBSM WIRING

Brown

Blue

Normally Open

Yellow

Normally Closed

Common

DIAGRAM 3: STRIKE MONITOR

DIAGRAM 2: LATCHBOLT MONITOR

Convert Mode

d. Verify the strike is now in the Fail Safe operation

mode. If the strike still operates as Fail Secure, be

sure screws are fully seated in the top position.

Verify

DIAGRAM 4: FAIL SAFE CONVERSION*

DIAGRAM 6: HORIZONTAL ADJUSTMENT

If horizontal adjustment is needed, 1 or 2

keeper shims can be added as illustrated below.

If adding a single shim use the

#4-40 x 1/8” Keeper Shim

Screws.

If adding both shims use the

#4-40 x 3/16” Keeper Shim

Screws.

One Shim

Both Shims

DIAGRAM 5: FACEPLATE OPTIONS

b. A Non-Handed center-lined faceplate is provided for

use with cylindrical locksets

a. A Non-Handed offset faceplate is provided for use

with mortise locksets. The mortise lock deadlatch

should be depressed by the faceplate when the

door is closed.

*USING THE 4500 FOR FAIL SAFE OPERATION NEGATES FIRE RATING

DIAGRAM 1: 12V to 24V CONVERSION

RED

RED/GREEN

BLACK

VIOLET

RED

BLACK

VIOLET

RED/GREEN

IF CONNECTOR IS MISSING

(+ 12 VDC)

(-NEG)

(+ 24 VDC)

(-NEG)

ELEC

TRIC

STRIKE

ELEC

TRIC

STRIKE

CONNECT

TOGETHER

CONNECT

TOGETHER

CONNECT

TOGETHER

Prepare Frame

4. Prepare frame using appropriate template for your

lockset on page 4. Schlage L9000 & Yale 8700 locksets

must use the template labeled “Schlage L9000 & Yale

8700 Locks Only.” All other locksets should use the

template labeled “CYLINDRICAL LOCKSET” or “MORTISE

LOCKSET.”

1. Select the appropriate Plug In Connector that matches

system power and electrically connect as illustrated in

Diagram 1. For 12V AC/DC or 16V AC, the pigtail marked

“12 VDC” should be used. For 24V AC/DC, the pigtail

marked “24 VDC” should be used.

2. If using Latchbolt Monitor (LBM) or Latchbolt Strike

Monitor (LBSM), see Diagram 2 & 3 on page 3 to com-

plete wiring. State of switch is listed for an unpowered

strike and LBM in unactuated (door open) position.

3. Verify that the strike is in the correct mode of

operation. This unit ships in Fail Secure mode. If you

need to convert to Fail Safe see Diagram 4 on page 3.

NOTE: FAIL SAFE CONVERSION NEGATES FIRE RATING.

aa

b

White
Orange
Green

Brown
Blue

Yellow

Fire Door

Safety Screw

Unpowered and in

unactuated state

Unpowered and in

unactuated state

a. Remove the Fire Door Safety Screw as illustrated.
b. Loosen the two #2-56 screws located on the back of

the strike as shown above, but do not remove them.
c. Move screws from the bottom of the hole (fail

secure position) to the top hole (fail safe position) and

re-tighten.