Installation diagrams, Diagram 5: cylindrical locksets, Diagram 5: fail safe conversion – HES 9400 User Manual

Page 3

Advertising
background image

3

Installation Diagrams

LBM WIRING

White

Orange

Normally Open

Green

Normally Closed

Common

DIAGRAM 4: STRIKE MONITOR

DIAGRAM 3: LATCHBOLT MONITOR

Normally Open

Yellow

Normally Closed

DIAGRAM 5: CYLINDRICAL LOCKSETS

LBSM WIRING

Brown

Blue

Normally Open

Yellow

Normally Closed

Common

DIAGRAM 5: FAIL SAFE CONVERSION

Convert Mode

The 9400 series Electric Strike is pre-set

for FAIL SECURE OPERATION as shown in

Figure 1.

There are Selector Stop Pins, one on the left

side and one on the right side. Both Selector

Stop Pins must be repositioned to convert

the strike to Fail Safe Operation.

1. To convert to Fail Safe Operation, remove

the Selector Stop Pins on each side of the

strike body using the 5/64” hex key

provided.

2. Move the Selector Stop Pins to the Fail

Safe Operation position as pictured

(towards the center of the strike) in Figure 2.

3. Tighten both Selector Stop Pins after they

have been moved to the Fail Safe Operation

Verify

Verify that both keepers are in Fail Safe

Operation. Both keepers should be

unlocked without power, but lock when

power is applied.

Figure 2: FAIL SAFE OPERATION

Figure 1: FAIL SECURE OPERATION

Selector Stop

Pin Location

Selector Stop

Pin Location

Brown

Blue

Yellow

White

Orange

Green