Installation diagrams, Diagram 5: cylindrical locksets, Diagram 5: fail safe conversion – HES 9400 User Manual
Page 3

3
Installation Diagrams
LBM WIRING
White
Orange
Normally Open
Green
Normally Closed
Common
DIAGRAM 4: STRIKE MONITOR
DIAGRAM 3: LATCHBOLT MONITOR
Normally Open
Yellow
Normally Closed
DIAGRAM 5: CYLINDRICAL LOCKSETS
LBSM WIRING
Brown
Blue
Normally Open
Yellow
Normally Closed
Common
DIAGRAM 5: FAIL SAFE CONVERSION
Convert Mode
The 9400 series Electric Strike is pre-set
for FAIL SECURE OPERATION as shown in
Figure 1.
There are Selector Stop Pins, one on the left
side and one on the right side. Both Selector
Stop Pins must be repositioned to convert
the strike to Fail Safe Operation.
1. To convert to Fail Safe Operation, remove
the Selector Stop Pins on each side of the
strike body using the 5/64” hex key
provided.
2. Move the Selector Stop Pins to the Fail
Safe Operation position as pictured
(towards the center of the strike) in Figure 2.
3. Tighten both Selector Stop Pins after they
have been moved to the Fail Safe Operation
Verify
Verify that both keepers are in Fail Safe
Operation. Both keepers should be
unlocked without power, but lock when
power is applied.
Figure 2: FAIL SAFE OPERATION
Figure 1: FAIL SECURE OPERATION
Selector Stop
Pin Location
Selector Stop
Pin Location
Brown
Blue
Yellow
White
Orange
Green