6 acquiring an edid, 1 acquiring the edid from a selected output, 2 restoring the default edid – Kramer Electronics VM-4Hxl User Manual

Page 12: Acquiring an edid, Acquiring the edid from a selected output, Restoring the default edid, On 6, 6acquiring an edid

Advertising
background image

VM-4Hxl - Acquiring an EDID

9

6

Acquiring an EDID

The VM-4Hxl initially operates with the default EDID. This means that you can turn

ON the power before connecting any of the acceptors or the source.

You can acquire the EDID by sending the:

EDID from a selected output to the input (see

Section 6.1

)

Default EDID to the input (see

Section 6.2

)

Auto EDID to the input (see

Section 6.3

)

The auto EDID is an adjusted calculation of the EDIDs of all the connected outputs.

6.1

Acquiring the EDID from a Selected Output

To select an EDID from a selected output, do the following:

1. Press the SELECT button, as required, to reach the desired output, which

flashes.

2. Press the READ button.

The EDID of the selected output is stored in the non-volatile memory when

the READ button no longer illuminates as well as the selected output LED.

6.2

Restoring the Default EDID

To restore the default EDID, do the following:

1. Press the SELECT button several times until the OUTPUT LEDs flash

simultaneously.

2. Press the READ button.

The READ button illuminates.

The default EDID is stored in the non-volatile memory when the READ

button no longer illuminates as well as the output LEDs.