1 storing a setup configuration, 2 recalling a setup configuration, 8 locking and unlocking the front panel buttons – Kramer Electronics VP-16x18AK User Manual

Page 28: 9 reading and writing the edid, Storing a setup configuration, Recalling a setup configuration, Locking and unlocking the front panel buttons, Reading and writing the edid, Section

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Operating the VP-16x18AK Locally via the Front Panel Buttons

24

7.7.1 Storing a Setup Configuration

To store the current status in memory:
1. Press the STO button

1

2. Press one of the OUTPUT SELECTOR buttons from 1 to 18. This is

the preset number in which the current status is stored.
The configuration is stored in the selected preset number.

.

The STO button flashes.

7.7.2 Recalling a Setup Configuration

To recall an input-output configuration:
1. Press the RCL button.

The RCL button flashes.

2. Press the required OUTPUT SELECTOR button (the OUTPUT

SELECTOR button number corresponding to the setup number).
The memory recalls the switching configuration from the selected
preset.

7.8

Locking and Unlocking the Front Panel Buttons

To lock the front panel buttons:

• Press and hold the Lock button until the button LED lights.

The buttons are locked

To unlock the front panel buttons:

• Press and hold the Lock button until the button LED is no longer lit.

The buttons are unlocked

7.9

Reading and Writing the EDID

The VP-16x18AK is delivered with default EDID data programmed in each
input. This can be modified by using the EDID Designer software

2

to read

and write EDID data via RS-232 or Ethernet.

1 Storing a new configuration over a previous configuration (without deleting it first) replaces the previous configuration

2 The software can be downloaded from

http://www.kramerelectronics.com

Advertising