10 default communication parameters, Default communication parameters – Kramer Electronics VP-4x1CS User Manual
Page 29

26
VP-4x1CS - Default Communication Parameters
10
Default Communication Parameters
RS-232
Protocol 2000
Protocol 3000 (Default)
Baud Rate:
9600
Baud Rate:
115,200
Data Bits:
8
Data Bits:
8
Stop Bits:
1
Stop Bits:
1
Parity:
None
Parity:
None
Command Format:
HEX
Command Format:
ASCII
Example (Output 1 to Input 1): 0x01, 0x81,
0x81, 0x81
Example (Output 1 to Input 1):
#AV
1>1<CR>
Switching Protocol
P2000 -> P3000
P3000 -> P2000
Command: 0x38, 0x80, 0x83, 0x81
Command:
#P2000<CR>
Front
Panel:
Press and hold Output 1 and
Output 3 simultaneously
Front Panel:
Press and hold Output 1 and
Output 2 simultaneously
Ethernet
Default Settings
Reset Settings
IP Address: 192.168.1.39
Power cycle the unit while holding in the
Factory Reset button, located on the rear
panel of the unit.
TCP Port #: 5000
UDP Port #: 50000