10 the vp-460 rs-232 communication protocol, 1 the protocol 3000 common operation commands, The vp-460 rs-232 communication protocol – Kramer Electronics VP-460 User Manual

Page 49: The protocol 3000 common operation commands

Advertising
background image

44

VP-460 - The VP-460 RS-232 Communication Protocol

10 The VP-460 RS-232 Communication Protocol

The Kramer Protocol lets you control the

VP-460 from any standard terminal

software (for example, the Windows

®

HyperTerminal Application).

This section describes the:

•

Protocol 3000 common commands, see

•

Audio video control commands (via protocol 3000), see

Section 10.1

•

The button functions (on the front panel and remote controller), see

Section 10.2

The protocol 3000 communications protocol uses a data rate of 115200 baud, with
no parity, 8 data bits, and 1 stop bit.

Section

10.3

10.1 The Protocol 3000 Common Operation Commands

Operation commands

Command

Syntax

Response

Lock front panel

LOCK-FP LOCK-MODE

LOCK-FP LOCK-MODE

RESULT

Get front panel

locking state

LOCK-FP?

LOCK-FP LOCK-MODE

Parameters Description:

LOCK-MODE

= Front panel locking state:

"0" or "off" to unlock front panel buttons.

"1" or "on" to lock front panel buttons.
Power state

POWER POWER-MODE

POWER POWER-MODE

RESULT

Get power state

POWER?

POWER POWER-MODE

Parameters Description:

POWER-MODE

= power state:

"0" or "off" to enter standby mode.

"1" or "on" to power up.

Restart device

RESET

RESET OK

Peripheral firmware

update execute*

UPGRADE

UPGRADE OK

Usually the firmware will upload to the device via a command such as LDFW

A device reset may be needed to complete the process
Video core Firmware UPGRADES

UPGRADES OK